Reproducibility of ambulatory esophageal pH monitoring in the aperistaltic esophagus

JP Shoenut, AB Micflikier, TAM Aldor, CS Yaffe… - Dysphagia, 1996 - Springer
… It is not clear at this time if the 24-h time period can be shortened [22], however, the high
reproducibility that is documented in this report may permit the monitoring time to be reduced. …

Basic principles of ambulatory pH monitoring and impedance

S Moosavi, A Rezaie, M Pimentel… - … , and pH Monitoring, 2020 - Springer
… recognize the pH gradient between the esophagus and stomach… esophageal dysmotility, and
aperistaltic esophagus. Given … reproducibility. Clin Gastroenterol Hepatol. 2013;11:366–72. …

[PDF][PDF] … of 24-h esophageal pH monitoring, capsule pH monitoring, combined pH monitoring with multichannel impedance, esophageal manometry, radiology and …

R Vardar, M Keskin - Turk J Gastroenterol, 2017 - academia.edu
… (distal and proximal esophagus), is superior to pH monitoring with single sensor capsules
in … manometric methods help clarify the diagnosis of aperistaltic disorders. Gastroenterology …

Characteristics and clinical relevance of proximal esophageal pH monitoring

M Cool, J Poelmans, L Feenstra… - Official journal of the …, 2004 - journals.lww.com
… motility in 26 patients (8%), segmental aperistalsispH probe in the upper esophagus, 20
cm above the LES ( 5, 26 ). However, the reproducibility of proximal esophageal pH monitoring

High-resolution manometry and impedance-pH/manometry: valuable tools in clinical and investigational esophagology

PJ Kahrilas, D Sifrim - Gastroenterology, 2008 - Elsevier
… A diagnosis of achalasia requires both aperistalsis and impaired deglutitive EGJ … esophagus;
and the proximal extent of reflux. Impedance–pH monitoring exhibits good reproducibility, …

New esophageal function testing (impedance, Bravo pH monitoring, and high-resolution manometry): clinical relevance

JA Wilson, MF Vela - Current gastroenterology reports, 2008 - Springer
… of reflux with MII-pH has been found to be reproducible [ 26 ], and … spanning the esophagus
(Z1–Z6) and pH changes from a single … A peristaltic wave progresses from proximal to distal …

Clinical applications of esophageal manometry and pH monitoring.

GA Ergun, PJ Kahrilas - American Journal of …, 1996 - search.ebscohost.com
… the esophagus and diminished or absent LES pressure. This description of aperistalsis in the
smooth muscle portion of the esophagus … have shown less reproducibility and considerable …

[PDF][PDF] … of 24-h esophageal pH monitoring, capsule pH monitoring, combined pH monitoring with multichannel impedance, esophageal manometry, radiology and …

M Keskin, R Vardar - 2017 - acikerisim-old.erbakan.edu.tr
… (distal and proximal esophagus), is superior to pH monitoring with single sensor capsules
in … manometric methods help clarify the diagnosis of aperistaltic disorders. Gastroenterology …

Esophageal impedance monitoring: clinical pearls and pitfalls

K Ravi, DA Katzka - Official journal of the American College of …, 2016 - journals.lww.com
… patients with hypersensitive esophagus from functional … all patients with achalasia or
aperistalsis had abnormal bolus … therapy and interobserver reproducibility. Clin Gastroenterol …

Esophageal function testing

A Wang, DK Pleskow, S Banerjee, BA Barth… - Gastrointestinal …, 2012 - giejournal.org
… generated by the esophagus or lower esophageal sphincter (… hour ambulatory simultaneous
impedance and pH monitoring… whether HRM data are more reproducible and can provide a …